title: "Cross-Site Transformers Are Robust Heart Rate Estimators"
source: "arXiv AI/CL/LG（论文）"
source_tier: "t2"
url: "https://arxiv.org/abs/2611.28366v1"
permalink: "https://feed.astralor.com/items/itm_316da1fe69cb77dbbfa2b4ff"
published: "2026-11-20T22:20:37.000Z"
score: 55
channel: "ai"
tags: ["Cross-Site Transformers Are","Robust Heart Rate","Estimators Single-site","PPG","Multi-site PPG","Single-site"]
---

# Cross-Site Transformers Are Robust Heart Rate Estimators

## At a glance

Single-site heart-rate estimation from photoplethysmography (PPG) degrades sharply under real-world motion. Multi-site PPG provides a natural solution, but existing models fuse sites as generic sensor channels rather th…

## Key points

- Single-site heart-rate estimation from photoplethysmography (PPG) degrades sharply under real-world motion.
- Multi-site PPG provides a natural solution, but existing models fuse sites as generic sensor channels rather than exploiting their hemodynamic structure: each heartbeat propagates along the arterial tree, appearing acro…
- We propose the Cross-Site Transformer, which introduces a hemodynamically informed inductive bias by restricting multi-sensor fusion to cross-attention between PPG sites.

## Full text

Single-site heart-rate estimation from photoplethysmography (PPG) degrades sharply under real-world motion. Multi-site PPG provides a natural solution, but existing models fuse sites as generic sensor channels rather than exploiting their hemodynamic structure: each heartbeat propagates along the arterial tree, appearing across body sites as delayed and transformed copies of the same cardiac event. We propose the Cross-Site Transformer, which introduces a hemodynamically informed inductive bias by restricting multi-sensor fusion to cross-attention between PPG sites. On WildPPG, the largest in-the-wild benchmark available, our model establishes a new single-model state of the art, reducing error by 21% over the previous best and 35% over the best prior transformer. The same cross-site restriction makes the trained network directly auditable. Because each cross-attention head lies on one directed pathway between sites, causal resample ablation can isolate and test each direction of information flow. Ablating the chest-to-wrist pathway doubles error, whereas the reverse costs far less. Encoding hemodynamic structure into attention routing thus improves real-world sensing robustness and enables rigorous auditing of multi-sensor fusion.

---

Verify against the original before citing; curated by Astral Feed: https://feed.astralor.com/items/itm_316da1fe69cb77dbbfa2b4ff