---
title: "A Cascaded Framework with a Cross-Attention-Guided Mamba-CNN Model for Pre- and Post-Treatment Glioma Segmentation"
source: "arXiv AI/CL/LG（论文）"
source_tier: "t2"
url: "https://arxiv.org/abs/2611.29792v1"
permalink: "https://feed.astralor.com/items/itm_89d75e07b1bc86fd1f14e4f4"
published: "2026-11-22T21:50:14.000Z"
score: 59
channel: "tech"
tags: ["推理效率","多模态","Cascaded Framework","Cross-Attention-Guided Mamba-CNN Model","Pre","Post-Treatment Glioma Segmentation","Accurate","Gliomas"]
---

# A Cascaded Framework with a Cross-Attention-Guided Mamba-CNN Model for Pre- and Post-Treatment Glioma Segmentation

## 速览

Accurate glioma segmentation is vital for diagnosis and follow-up, but manual segmentation is time-consuming, subjective, and variable across interpreters. Gliomas are heterogeneous in size, shape, and location. Deep le…

## 关键点

- Accurate glioma segmentation is vital for diagnosis and follow-up, but manual segmentation is time-consuming, subjective, and variable across interpreters.
- Gliomas are heterogeneous in size, shape, and location.
- Deep learning has therefore emerged as a potential solution.

## 全文

Accurate glioma segmentation is vital for diagnosis and follow-up, but manual segmentation is time-consuming, subjective, and variable across interpreters. Gliomas are heterogeneous in size, shape, and location. Deep learning has therefore emerged as a potential solution. CNNs excel at local features but may struggle with long-range dependencies, whereas Vision Transformers capture global context efficiently but incur higher computational complexity. Most previous studies focused on pre-treatment gliomas; post-treatment cases with resection cavities (RCs) remain less explored. This study proposes a Cross-Attention-Guided Mamba-CNN (CMC-Seg) model within a cascaded framework for pre- and post-treatment diffuse glioma segmentation, aiming to balance accuracy and computational cost. Experiments used BraTS 2025 mpMRI of diffuse glioma patients. After preprocessing, a coarse segmentation model extracted tumor-centered patches, which were fed to CMC-Seg for fine-grained segmentation. CMC-Seg was compared with 3D U-Net, SegResNet, SwinUNETR, UNETR, nnFormer, and SegMamba. On the test set, CMC-Seg achieved the highest mean Dice (81.20%) and non-enhancing tumor core (NETC) Dice (77.09%). It also achieved an RC Dice of 78.63% and the lowest 95% Hausdorff distance (HD95; 4.39 mm). Results were comparable to CNN and Mamba baselines and significantly better than Transformer-based baselines (P < 0.05). CMC-Seg required the fewest inference GFLOPs (381.49). Ablation experiments indicated that multi-direction scanning and cross-attention improved performance, particularly for RC (P < 0.05). Grad-CAM explainability experiments showed that CMC-Seg focuses on diagnostically relevant tumor regions.

---

引用前请核对原文;本文由星际流动整理:https://feed.astralor.com/items/itm_89d75e07b1bc86fd1f14e4f4
