# PtychoFM: A Foundation Model for Ptychographic Imaging

## At a glance

Ptychography provides high-resolution lensless imaging across X-ray, electron, and optical microscopy, but reconstructing images from diffraction measurements generally requires computationally intensity iterative phase…

## Key points

- Ptychography provides high-resolution lensless imaging across X-ray, electron, and optical microscopy, but reconstructing images from diffraction measurements generally requires computationally intensity iterative phase…
- These methods often require experiment-specific analysis, limiting real-time feedback as data acquisition rates increase.
- Here, we demonstrate PtychoFM, a physics-aware foundation model for ptychographic imaging that combines large-scale pre-training with experiment-specific fine-tuning to reconstruct complex object images directly from in…

## Full text

Ptychography provides high-resolution lensless imaging across X-ray, electron, and optical microscopy, but reconstructing images from diffraction measurements generally requires computationally intensity iterative phase retrieval. These methods often require experiment-specific analysis, limiting real-time feedback as data acquisition rates increase. Here, we demonstrate PtychoFM, a physics-aware foundation model for ptychographic imaging that combines large-scale pre-training with experiment-specific fine-tuning to reconstruct complex object images directly from individual diffraction patterns. Trained using a differentiable forward model without object-space labels, PtychoFM transfers from step-scan training data on one sample to fly-scan measurements of other samples with different feature sizes, morphologies, and refraction indices. At a synchrotron beamline, diffraction frames were streamed from the detector to a single GPU for inference at up to 200 frames per second and returned for real-time visualization. PtychoFM provides a practical route to rapid, transferable ptychographic reconstruction and live experimental feedback under nonideal conditions.

---