# Adaptive Reliability Reserves for Residential Battery Fleets

## 速览

In a Houston 2024 replay, replacing a fixed 20 percent battery reserve with a county-risk threshold raises observed five-hour backup coverage from 75.0 percent to 86.5 percent and adds USD 10.2 in modeled annualized mar…

## 关键点

- In a Houston 2024 replay, replacing a fixed 20 percent battery reserve with a county-risk threshold raises observed five-hour backup coverage from 75.0 percent to 86.5 percent and adds USD 10.2 in modeled annualized mar…
- The paired coverage-gain interval includes zero.
- This is a conditional simulation result, not measured company reliability.

## 全文

In a Houston 2024 replay, replacing a fixed 20 percent battery reserve with a county-risk threshold raises observed five-hour backup coverage from 75.0 percent to 86.5 percent and adds USD 10.2 in modeled annualized margin per home (paired 95 percent interval: USD +1.7 to USD +21.7). The paired coverage-gain interval includes zero. This is a conditional simulation result, not measured company reliability. Residential batteries face this tradeoff because market discharge consumes energy also needed for household outages. We release HomeFleet-ERCOT, combining observed prices and county outages with identified simulated homes and causal controller inputs. We compare independent-home optimization with 21 proximal policy optimization (PPO) training runs; ten promise-cost candidates span 31.1 percent-96.3 percent backup coverage. Of these, 10 have lower modeled margin than fixed 20 percent, and 3 also have lower coverage. Chronological, geographic, fleet, and storm tests examine transfer. An alert charging override has a conditional energy-and-power sufficiency guarantee, but only 19.5 percent of 41 county mass-outage episodes provide enough continuous warning for every battery preset. Synthetic tests include short, missed, and false warnings, load uplift, capacity loss, and dropout. A static AC audit retains existing feeder violations; aging comparisons expose model sensitivity. The released benchmark, controllers, and checkpoints provide a reproducible basis for comparing these tradeoffs. This work supports the design of residential battery programs that assess market value and household backup service together.

---